CDE Detailed Report
Subdomain Name: Biomechanical Devices
CRF: Head Kinematics Estimates Form
Displaying 101 - 105 of 105
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C56866 | Biomechanical device mouth guard type | BiomechDevMouthGuardTyp | The type of mouth guard where the biomechanical device is mounted | The type of mouth guard where the biomechanical device is mounte | For mouth guard: | Custom;Boil-and-bite model | Custom;Boil-and-bite model | Alphanumeric | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-08-03 14:16:03.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Single Pre-Defined Value Selected |
|||||||||
C56890 | Gyroscope sample rate value | GyroscopeSampleRtVal | The value related to rate of sampling of the gyroscope | The value related to rate of sampling of the gyroscop | Gyroscope sampling rate: | Numeric Values |
(if sensors have different sample rates) |
Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-08-03 15:11:00.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
Hertz | |||||||||
C56933 | Head impact finite element model version name | HeadImpFEModelVersionNam | The name of the finite element head impact modeling | The name of the finite element head impact modelin | FE Model Version: | Alphanumeric |
Currently, it is not typical to report a model version number except for a few (GHBMC/THUMS). Recommend to report a major and a minor version number in the future, e.g., Version 1.0, Version 2.1. Also recommend providing citation of the model description and validation for the specific model. Need to further discuss what constitutes a major version vs. a minor version – for example, change of head/brain meshing, change of material property (isotropic vs. anisotropic), etc. may constitute a major version, while geometrical scaling and revision on brain-skull boundary conditions, etc. may be a minor version. |
Adult;Pediatric | Exploratory | 1.00 | 2017-08-04 08:29:26.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events | 255 |
Free-Form Entry |
||||||||||
C01522 | Height measurement | HgtMeasr | Measurement of participant's height | Measurement of participant's height | Subject height: | Numeric Values | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:49:20.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
0 | 400 | centimeter | 649 | |||||||
C58452 | Helmet size other text | HelmetSizeOTH | The other specify for the size of helmet worn by the subject/participant | The other specify for the size of helmet worn by the subject/participan | Specify | Alphanumeric | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2017-08-03 14:05:22.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events | 255 |
Free-Form Entry |
- « first
- ‹ previous
- 1
- 2
- 3