CDE Detailed Report

Disease: Traumatic Brain Injury
Subdomain Name: Biomechanical Devices
CRF: Head Kinematics Estimates Form

Displaying 1 - 50 of 105
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C57005 Data storage trigger threshold value DtStTrgThrsVl Value of data storage (trigger) threshold Value of data storage (trigger) threshold Data Storage (trigger) threshold: Numeric Values

This is the trigger threshold used to trigger an impact. Specifed as linear acceleration, angular acceleration, angular velocity or a combination (check all that apply). Also, if the algorithm requires the signal to exceed a given threshold for a minimum amount of time that should be included as 'MTOM, minimum time over threshold, samples or ms for units'. Specify if triggering is possible independently by axis and enter each if so. Check proprietary option and provide practical threshold in practice as well. Fill trigger for a minimum amount of time that should be included as 'MTOM, minimum time over threshold, samples or ms for units' Specify if triggering is possible independently by axis and enter each if so. Check proprietary option and provide practical threshold in practice as well.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-12-06 12:05:44.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C56787 Sport type SportTyp The type of sport that the participant/subject plays or was playing The type of sport that the participant/subject plays or was playin Sport: Baseball;Basketball;Beach Volleyball;Biking;Bowling;Boxing;Cheerleading;Cross Country / Track;Diving;Fencing;Field;Field Hockey;Football;Golf;Gymnastics;Ice Hockey;In Line Hockey;Lacrosse;Rifle;Rowing/Crew;Rugby;Sailing;Skiing;Soccer;Sprint Football;Squash;Swimming;Tennis;Volleyball;Water polo;Wrestling;Softball;Other, specify Baseball;Basketball;Beach Volleyball;Biking;Bowling;Boxing;Cheerleading;Cross Country / Track;Diving;Fencing;Field;Field Hockey;Football;Golf;Gymnastics;Ice Hockey;In Line Hockey;Lacrosse;Rifle;Rowing/Crew;Rugby;Sailing;Skiing;Soccer;Sprint Football;Squash;Swimming;Tennis;Volleyball;Water polo;Wrestling;Softball;Other, specify Alphanumeric

Select from the list of permissible values below. Note: This information may make the data personal identifiable along with position

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental 1.00 2017-07-24 13:54:29.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Multiple Pre-Defined Values Selected

C56909 Head impact peak linear acceleration y value HeadImpPeakLinearAccelerYVal The value of peak linear acceleration in the y direction in head impact assessment The value of peak linear acceleration in the y direction in head impact assessmen Peak linear acceleration y: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:45:50.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C56921 Head impact peak rotational acceleration z value HeadImpPeakRotatAccelZVal The value of peak rotational acceleration in the z direction in head impact assessment The value of peak rotational acceleration in the z direction in head impact assessmen Peak rotational acceleration z: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 15:45:50.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C57016 Gyroscope nominal non-linear value GyrNmNnLnrVal Value of gyroscope nominal non-linearity (% of output) Value of gyroscope nominal non-linearity (% of output) Gyroscope nominal non-linearity (% of output) Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-12-06 15:53:33.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56865 Biomechanical device mount location type BiomechDeviceMountLocationTyp The type of location where the biomechanical device/sensor is mounted The type of location where the biomechanical device/sensor is mounte Device mounting location [or interface and location]: Helmet;Mouth guard;Left ear;Right ear;Skin;Teeth;Ear canal;Other, specify Helmet;Mouth guard;Left ear;Right ear;Skin;Teeth;Ear canal;Other Alphanumeric

Location of placement of final assembled device, including helmet (inside helmet), mouthguard, ear (lef or right), skin, teeth, ear canal or other (specify). Fill in the appropriate device mounting location or interface and location per the instructions.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 14:08:16.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56932 Head impact finite element model name HeadImpFEModelName The name of the finite-element head impact modeling The name of the finite-element head impact modelin FE Model Name: ABM;GHBMC;THUMS;WHIM;Other, specify ABM;GHBMC;THUMS;WHIM;Other, specify Alphanumeric

Abbreviation of the head injury model name used; e.g., ABM, GHBMC, THUMS, WHIM, etc.

Adult;Pediatric Exploratory 1.00 2017-08-04 08:28:43.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C01520 Head circumference measurement HeadCircumfMeasr Circumferential measurement of the head at the widest point - the distance from above the eyebrows and ears and around the back of the head Circumferential measurement of the head at the widest point - the distance from above the eyebrows and ears and around the back of the head Subject head size (circumference): Numeric Values

Head circumference should be measured with a non-stretch tape held firmly, but without squeezing skin, in the horizontal plane through the glabella (forehead above the eyebrows) and opisthocranion [posteriormost point of the occiput]. https://www.ejmanager.com/mnstemps/134/1997_4_3_1.pdf

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

0 100 centimeter 3181613
C58451 Biomechanical device sensor other text BiomechanicalDeviceSenOTH The other specify for type of biomechanical device/sensor used to collect data The other specify for type of biomechanical device/sensor used to collect dat Specify Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 13:56:27.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56889 Gyroscope range GyroscopeRng The range of the gyroscope The range of the gyroscop Gyroscope full scale range +/- (rad/s): Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:10:24.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C57006 Accelerometer nominal non-linearity value AccNmNnLnrVal Value of accerlerometer nominal non-linearity (% of output) Value of accerlerometer nominal non-linearity (% of output) Accelerometer nominal non-linearity, (% of output): Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-12-06 14:07:59.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

percent
C56855 Sport position type SportPositionTyp The type of sport position played by the subject/participant The type of sport position played by the subject/participan Position: Base Coach;Base Runner;Batter;Catcher;Center Field;First Base;Left Field;Participant;Pitcher;Right Field;Second Base;Short Stop;Third Base;Center;Forward;Guard;Rider;102lbs;105lbs;108lbs;112lbs;115lbs;118lbs;122lbs;126lbs;130lbs;135lbs;140lbs;147lbs;154lbs;160lbs;168lbs;175lbs;200lbs;Heavyweight;Base;Flyer;Back Spotter;Front Spotter;Unknown;Diver;Decathlete;Heptathlete;Jumper;Pentathlete;Runner;Thrower;Pole Vaulter;Defensive Back;Forward/Attack;Goalkeeper;Midfielder;Cornerback;Defensive End;Defensive Tackle/Nose Guard;Flanker/Wide Receiver;Holder;Punter/Kicker;Linebacker;Long Snapper;Off (tight) End;Off Guard;Off Tackle;Quarterback;Running Back/Slotback;Safety;Special Teams (FG Offense);Special Teams (FG Defense);Special Teams (Punt Return);Special Teams (Punt Coverage);Special Teams (Kickoff Coverage);Special Teams (Kickoff Return);Defense Right;Defense Left;Forward Attack;Goal Keeper;Wing (left);Wing (right);Middlefield;Coxwain;Port;Starboard;Loosehead Prop;Hooker;Tighthead Prop;Second Row;Blindside Flanker;Openside Flanker;Number 8;Scrum-half;Fly-half;Alpine;Cross Country;Singles;Doubles;Swimmer;Libero;Middle Blocker;Outside Hitter;Setter;125lbs;133lbs;141lbs;149lbs;157lbs;165lbs;174lbs;184lbs;197lbs;Opposite/Right side Hitter Base Coach;Base Runner;Batter;Catcher;Center Field;First Base;Left Field;Participant;Pitcher;Right Field;Second Base;Short Stop;Third Base;Center;Forward;Guard;Rider;102lbs;105lbs;108lbs;112lbs;115lbs;118lbs;122lbs;126lbs;130lbs;135lbs;140lbs;147lbs;154lbs;160lbs;168lbs;175lbs;200lbs;Heavyweight;Base;Flyer;Back Spotter;Front Spotter;Unknown;Diver;Decathlete;Heptathlete;Jumper;Pentathlete;Runner;Thrower;Pole Vaulter;Defensive Back;Forward/Attack;Goalkeeper;Midfielder;Cornerback;Defensive End;Defensive Tackle/Nose Guard;Flanker/Wide Receiver;Holder;Punter/Kicker;Linebacker;Long Snapper;Off (tight) End;Off Guard;Off Tackle;Quarterback;Running Back/Slotback;Safety;Special Teams (FG Offense);Special Teams (FG Defense);Special Teams (Punt Return);Special Teams (Punt Coverage);Special Teams (Kickoff Coverage);Special Teams (Kickoff Return);Defense Right;Defense Left;Forward Attack;Goal Keeper;Wing (left);Wing (right);Middlefield;Coxwain;Port;Starboard;Loosehead Prop;Hooker;Tighthead Prop;Second Row;Blindside Flanker;Openside Flanker;Number 8;Scrum-half;Fly-half;Alpine;Cross Country;Singles;Doubles;Swimmer;Libero;Middle Blocker;Outside Hitter;Setter;125lbs;133lbs;141lbs;149lbs;157lbs;165lbs;174lbs;184lbs;197lbs;Opposite/Right side Hitter Alphanumeric

The primary position of the participant at the time of the event(s). Select from list of permissible values for each sport. Note: Depending on the sample size, this data may be personally identifiable. It is up to the researcher to determine if this information should be collected.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 13:28:03.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Multiple Pre-Defined Values Selected

C56910 Head impact peak linear acceleration z value HeadImpPeakLinearAccelerZVal The value of peak linear acceleration in the z direction in head impact assessment The value of peak linear acceleration in the z direction in head impact assessmen Peak linear acceleration z: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:45:50.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C56922 Head impact peak rotational acceleration magnitude value HeadImpPeakRotatAccelMagVal The value of peak rotational acceleration magnitude measured in radian or degree for head impact assessment The value of peak rotational acceleration magnitude measured in radian or degree for head impact assessmen Peak rotational acceleration magnitude: Numeric Values

Radian or Degree

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 15:45:50.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Radian or degree
C57017 Gyroscope 0dB pass band value Gyr0dBPssBndVal Value of the gyroscope 0dB pass-band (f1-f2, Hz) Value of the gyroscope 0dB pass-band (f1-f2, Hz) Gyroscope 0dB pass-band (f1-f2, Hz): Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-12-06 15:57:23.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56866 Biomechanical device mouth guard type BiomechDevMouthGuardTyp The type of mouth guard where the biomechanical device is mounted The type of mouth guard where the biomechanical device is mounte For mouth guard: Custom;Boil-and-bite model Custom;Boil-and-bite model Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 14:16:03.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56933 Head impact finite element model version name HeadImpFEModelVersionNam The name of the finite element head impact modeling The name of the finite element head impact modelin FE Model Version: Alphanumeric

Currently, it is not typical to report a model version number except for a few (GHBMC/THUMS). Recommend to report a major and a minor version number in the future, e.g., Version 1.0, Version 2.1. Also recommend providing citation of the model description and validation for the specific model. Need to further discuss what constitutes a major version vs. a minor version – for example, change of head/brain meshing, change of material property (isotropic vs. anisotropic), etc. may constitute a major version, while geometrical scaling and revision on brain-skull boundary conditions, etc. may be a minor version.

Adult;Pediatric Exploratory 1.00 2017-08-04 08:29:26.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C01522 Height measurement HgtMeasr Measurement of participant's height Measurement of participant's height Subject height: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 3.10 2024-02-29 15:49:20.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

0 400 centimeter 649
C58452 Helmet size other text HelmetSizeOTH The other specify for the size of helmet worn by the subject/participant The other specify for the size of helmet worn by the subject/participan Specify Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 14:05:22.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56890 Gyroscope sample rate value GyroscopeSampleRtVal The value related to rate of sampling of the gyroscope The value related to rate of sampling of the gyroscop Gyroscope sampling rate: Numeric Values

(if sensors have different sample rates)

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:11:00.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Hertz
C57007 Accelerometer calibration type calibration constant type AccClbTypClbCnsTyp Type of accelerometer calibration and calibration constants Type of accelerometer calibration and calibration constants Accelerometer calibration type and calibration constants: None;Linear Y=mX+B;non-linear Y=KX^n None;Linear Y=mX+B;non-linear Y=KX^n Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-12-06 14:12:51.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56856 Sport competition level type SportCompLevelTyp The level of competition related to the sport in which the subject participated The level of competition related to the sport in which the subject participate Subject's competition level: Club;College;High School;Rec Club level sport competition;College;High School;Recreational level sport competition Alphanumeric

Competition level of practice or game participated in by subject at time of recording of exposure event. Determine competition level based on official practice or competition category. If other, or laboratory/ exploratory, etc, record if so. Note: Recreation ('Rec') is non-competitive recreational sport while competitive recreational is referred to as 'Club'.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 13:32:00.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56911 Angular velocity unit of measure AngularVelocityUOM The unit of measure for angular velocity The unit of measure for angular velocit Angular velocity units: rad/s;deg/s rad/s=radians per second;deg/s=degrees per second Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 16:00:18.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56923 Head Injury Criterion (HIC) - Calculated average value HeadInjuryCriterionCalAveVal The calculated average value of the Head Injury Criterion (HIC) which is based on the average value of the acceleration over the most critical part of the deceleration The calculated average value of the Head Injury Criterion (HIC) which is based on the average value of the acceleration over the most critical part of the deceleratio Head Injury Criterion (HIC) Numeric Values

Linear acceleration using "g" as unit, time "ms" as unit.
See REF for equation.

Versace, J. A Review of the Severity Index. Warrendale, PA: SAE International, 1971. Adult;Pediatric Exploratory 1.00 2017-08-03 16:23:27.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C57018 Analog pre-filter type AnlgPrFltrTyp Type of analog pre-filter type (gyroscope) Type of analog pre-filter type (gyroscope) Analog pre-filter type None;4th Order Butterworth;Brick Wall;Other, specify: None;4th Order Butterworth;Brick Wall;Other, specify: Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-12-06 16:11:00.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56867 Biomechanical device hardware version number BiomechDevHardwareVersionNum The version number related to the hardware for the biomechanical sensor/device The version number related to the hardware for the biomechanical sensor/devic Hardware Version: Alphanumeric

Per vendor- hardware number for final assembled device for vendor sensor hardware and date of manufacture if available. Fill in the appropriate hardware version per the definition

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 14:18:42.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56936 Biomechanical device mount location other text BiomechDeviceMountLocationOTH The free-text field to specify the other location where the biomechanical device/sensor is mounted The free-text field to specify the other location where the biomechanical device/sensor is mounte Other, specify: Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 14:08:16.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C01523 Head circumference unit of measure HdCircumfUoM Unit of measure for the head circumference numerical value Unit of measure for the head circumference numerical value Inches;Centimeters Inches;Centimeters Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 3.00 2013-07-24 21:00:23.88 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

3181626
C58453 Biomechanical device lab kinematic calibration type BiomechDevLabKinemticCalibrTyp The type laboratory kinematic calibration for the biomechanical device The type laboratory kinematic calibration for the biomechanical devic Laboratory ranges of kinematic calibration for instrument: Custom calibration;Standard sensor start rating Custom calibration;Standard sensor start rating Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-08-03 14:26:53.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56893 Gyroscope response frequency value GyroscopeResponseFrequencyVal The value of the frequency response of the gyroscope The value of the frequency response of the gyroscop Gyroscope filter -3dB corner frequency, (Hz): Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 15:14:02.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Hertz
C57008 Accelerometer 0dB pass band value AccOdBPssBndVal Value of accelerometer 0dB pass band (f1-f2, Hz) Value of accelerometer 0dB pass band (f1-f2, Hz) Accelerometer 0dB pass-band, (f1-f2, Hz): Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-12-06 14:41:57.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Hertz
C56857 Sport activity category SportActivityCat The category of the sport activity the subject was participating in during the time of the event The category of the sport activity the subject was participating in during the time of the even Activity at time of event: Game;Practice;Scrimmage;Warm-up Game;Practice;Scrimmage;Warm-up Alphanumeric

Select from the options provided. 'Warm-up' may not be discernible and may not be included in the options.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 13:39:33.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56913 Head impact angular velocity pulse frequency value HeadImpAngularVelPulseFreqVal The value of the frequency content of angular velocity pulse in head impact assessment The value of the frequency content of angular velocity pulse in head impact assessmen Frequency content of angular velocity pulse (Hz-if different than linear acceleration): Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-08-03 15:43:07.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Hertz
C56924 Gadd Severity Index (SI) - Severity value GADDSISeverityVal The value of the Gadd Severity Index (SI) based on head tolerance limit and linear acceleration The value of the Gadd Severity Index (SI) based on head tolerance limit and linear acceleratio Severity Index (SI) Numeric Values

It was formulated by fitting the Wayne State Tolerance Curve, which is based on skull fracture data. It incorporates impact duration into the assessment of head and brain injury risk. Linear acceleration using "g" as unit, time "ms" as unit.

See Ref for equation.

The integral is evaluated over the period of time from when the linear acceleration first exceeds 4g to when it returns to 4g after the largest peak.

Gadd, C. W. Use of a weighted-impulse criterion for esti- mating injury hazard. SAE Technical Paper, 1966. Adult;Pediatric Exploratory 1.00 2017-08-03 16:24:52.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C57019 Angular velocity sensor angular acceleration derivative indicator AngVlcSnsAngAccDrvInd Indicator of angular velocity sensor are angular accelerations derivatives Indicator of angular velocity sensor are angular accelerations derivatives If angular velocity sensor, are angular accelerations derivatives No;Yes No;Yes Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-12-06 16:52:09.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56868 Biomechanical device sensor firmware version number code BiomechDevSenFirmwaVersNumCode The number related to the firmware version of a biomechanical device/sensor The number related to the firmware version of a biomechanical device/senso Sensor Firmware Version: Alphanumeric

Per vendor- firmware hardware version number and date of firmware if available. Fill in the appropriate firmware version per the definition

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 14:18:42.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56955 Head impact linear acceleration pulse frequency value HeadImpLinAccelPulseFreqVal The value of the frequency content of linear acceleration pulse in head impact assessment The value of the frequency content of linear acceleration pulse in head impact assessmen Estimated frequency content of linear acceleration pulse, to compare against sensor optimal ranges of performance (Hz): Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-08-03 15:43:07.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

Hertz
C01541 Weight measurement WgtMeasr Measurement of participant's weight Measurement of participant's weight Subject weight: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 3.10 2024-02-29 15:49:21.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

0 500 kilogram 2179689
C58454 Head Injury Criterion (HIC) - Type HeadInjuryCriterionTyp The specified HIC15 or HIC36 used to calculated average value of the Head Injury Criterion (HIC) which is based on the average value of the acceleration over the most critical part of the deceleration The specified HIC15 or HIC36 used to calculated average value of the Head Injury Criterion (HIC) which is based on the average value of the acceleration over the most critical part of the deceleratio Head Injury Criterion (HIC) Specify HIC15;HIC36 HIC15;HIC36 Alphanumeric

Linear acceleration using "g" as unit, time "ms" as unit.
See REF for equation.

Versace, J. A Review of the Severity Index. Warrendale, PA: SAE International, 1971. Adult;Pediatric Exploratory 1.00 2017-08-03 16:23:27.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56897 Data transform sensor coordinate system definition text DataTransformCoordinateDefTxt The free-text field to indicate the sensor coordinate system definition for transformation of data The free-text field to indicate the sensor coordinate system definition for transformation of dat If no, indicate sensor coordinate definition for transformation purposes: Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:20:24.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C57009 Accelerometer analog pre-filter type AccAnlgPrFltrTyp Type of accelerometer analog pre-filter Type of accelerometer analog pre-filter Accelerometer analog pre-filter type: None;4th Order Butterworth;Other, specify None;4th Order Butterworth;Other, specify Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-12-06 14:50:31.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56858 Biomechanical device count category BiomechanicalDeviceCtCat The category related to count of biomechanical devices used to collect data The category related to count of biomechanical devices used to collect dat Device Single;Multiple Single;Multiple Alphanumeric

Single or multipledevices (not sensors) used for data collection. If multiple devices are used, will require entry for each device. Check appropriate box. If multiple devices are employed, information will be required for each device

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Exploratory 1.00 2017-08-03 13:44:49.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56914 Head impact rotational velocity x peak change value HeadImpRotatVelXPeakChVal The value of the peak change in rotational velocity in the x direction in head impact assessment The value of the peak change in rotational velocity in the x direction in head impact assessmen Peak change in rotational velocity x: Numeric Values Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-08-03 15:45:50.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C56925 Brain Injury Criterion (BrIC) - Calculated value BrainInjuryCriterionCalVal The calculated value of the Brain Injury Criterion (BriC) a kinematic rotational metric for assessing brain injury The calculated value of the Brain Injury Criterion (BriC) a kinematic rotational metric for assessing brain injur Brain Injury Criterion (BrIC) Numeric Values

Formulated using the maximum magnitudes of the three orthogonal head angular velocity components.

Critical velocity values are model-dependent, and also rely on an injury dataset to produce the 50% injury probability.

Takhounts, E. G., M. J. Craig, K. Moorhouse, J. McFadden, and V. Hasija. Development of brain injury criteria (Br IC). Stapp Car Crash J. 57:243&#8211;266, 2013. Adult;Pediatric Exploratory 1.00 2017-08-03 16:25:43.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C57020 Gyroscope derivation method type GyrDrvMthTyp Type of Gyroscope derivation method Type of Gyroscope derivation method Derivation method Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-12-06 16:58:12.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56869 Biomechanical head device type BiomechanHeadDeviceTyp The type of biomechancial device used to collect data The type of biomechancial device used to collect dat Device Type: Ear piece;Helmet liner;Custom mouth guard;Boil-and-Bite Mouth guard (injection molded, 3D printed);retainer;Skin patch;Headband;Other specify Ear piece;Helmet liner;Custom mouth guard;Boil-and-Bite Mouth guard (injection molded, 3D printed);retainer;Skin patch;Headband;Other specify Alphanumeric

Ear piece, helmet liner, custon mouth guard (thermoformed, 3D printed), boil-and-bite mouth guard (injection molded, 3D printed), retainer, skin patch, headband, other (specify). Record the general device type as advertised and under intended use.

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 14:21:08.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

C56999 Data collected start date and time DtCllcStrtDateTime Date/Time of start of data collection Date/Time of start of data collection Date of first event
Time of last event
Date or Date & Time

Report the time and date when the first event was recorded

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 1.00 2017-12-04 14:50:18.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Free-Form Entry

C01581 Weight unit of measure WgtUoM Unit of measure for the weight numerical value Unit of measure for the weight numerical value Pounds;Kilograms Pounds;Kilograms Alphanumeric Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659&#8211;2668 Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

2630200
C58455 Head impact finite element model name other text HeadImpFEModelNameOTH The other specify name of the finite-element head impact modeling The other specify name of the finite-element head impact modelin Specify Alphanumeric

Abbreviation of the head injury model name used; e.g., ABM, GHBMC, THUMS, WHIM, etc.

Adult;Pediatric Exploratory 1.00 2017-08-04 08:28:43.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events 255

Free-Form Entry

C56898 Society of Automotive Engineers impact test data filter indicator SAEImpTestDataFilterInd The indicator related to whether data was filtered based on standards according to Society of Automotive Engineers for impact testing (SAE J211) The indicator related to whether data was filtered based on standards according to Society of Automotive Engineers for impact testing (SAE J211 Are the data filtered based on standards according to SAE J211?: No;Yes No;Yes Alphanumeric

The current data standard should be used (e.g., future consideration of use of SAE J1734).

Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 Adult;Pediatric Supplemental-Highly Recommended 1.00 2017-08-03 15:23:22.0 Head Kinematics Estimates Form Biomechanical Devices Disease%2FInjury Related Events

Single Pre-Defined Value Selected

CSV