CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: Magnetoencephalography (MEG)
Displaying 101 - 127 of 127
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C56622 | Imaging magnetoencephalography head localization during recording other text | ImagMEGHeadLocalDurRecOthrTxt | Text describing another type of head localization used for measuring head movement during recording | Text describing another type of head localization used for measuring head movement during recordin | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-19 14:45:28.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C56720 | Imaging magnetoencephalography waveform latency amplitude habituation result | ImagMEGWaveLatAmpHabRes | Results of waveform latency/amplitude/habituation measures/comparison of the magnetoencephalography (MEG) study | Results of waveform latency/amplitude/habituation measures/comparison of the magnetoencephalography (MEG) stud | Waveform latency/amplitude/habituation measures/comparison results | Alphanumeric |
No additional instructions |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 15:08:42.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C56654 | Imaging response box pad status | ImagRespnsBoxPadStat | The status of the response boxes/pads during data acquisition | The status of the response boxes/pads during data acquisitio | Response boxes/pads (motor) | On;Off | On;Off | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 10:20:06.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56665 | Imaging magnetoencephalography other device system in magnetic shielded room text | ImgMEGOthrDevSysMagShldRoomTxt | Text specifying any other devices or systems present in the magnetic shielded room | Text specifying any other devices or systems present in the magnetic shielded roo | Specify other devices/systems in the magnetic shielding room | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 10:51:00.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C14047 | Magnetoencephalography/ electroencephalography source analysis beamformer type | MEGEEGSrcAnlysisBeamformerTyp | A signal processing technique used for determining location of electric activity that can be accomplished via different approaches | A signal processing technique used for determining location of electric activity that can be accomplished via different approaches | Beamforming (spatial filtering) | Vector;SAM;Scalar beamformer;Vector-scale beamformer (2 Step);Other, specify | Vector;Synthetic Aperture Magnetometry (SAM);Scalar beamformer;Vector-scale beamformer (2 Step);Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-08-28 16:08:00.453 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56699 | Imaging magnetoencephalography reconstruction dipole modeling type | ImagMEGReconDipModTyp | The type of dipole modeling used for magnetoencephalography (MEG) reconstruction | The type of dipole modeling used for magnetoencephalography (MEG) reconstructio | Dipole modeling | Multiple dipole;Single dipole;Moving dipole;Other, specify | Multiple dipole;Single dipole;Moving dipole;Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 11:38:13.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56633 | Imaging epoch time | ImagEpochTime | The time that the epoch (trial) lasted | The time that the epoch (trial) laste | Epoch (trial) time | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 09:25:37.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||||
C56676 | Imaging magnetoencephalography waveform all trial average value | ImagMEGWaveAllTrialAvgVal | The waveform average value for all trials of magnetoencephalography (MEG) processing | The waveform average value for all trials of magnetoencephalography (MEG) processin | All trial averaging | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 10:33:50.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||||
C56612 | Imaging magnetoencephalography scanner used count | ImagMEGScanUsedCt | The number of different MEG scanners that were used on the subject | The number of different MEG scanners that were used on the subjec | Number of different MEG scanners used | Numeric Values |
Report the number of different MEG systems hat were used for recording MEG data from participants during the study. |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-05-31 12:11:13.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C56710 | Imaging magnetoencephalography topographic distribution type | ImagMEGTopoDistTyp | The type of topographic distribution used for analysis of the magnetoencephalography (MEG) data | The type of topographic distribution used for analysis of the magnetoencephalography (MEG) dat | Topographic distribution | Spatial pattern;Focal;Other, specify;Diffusive | Spatial pattern;Focal;Other, specify;Diffusive | Alphanumeric |
No additional instructions |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 13:58:35.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C56644 | Imaging actual used acquisition time | ImagActUsedAcqTime | The actually used acquisition time for the imaging | The actually used acquisition time for the imagin | Total acquisition time: Actually used | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 09:50:24.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond per second | |||||||||||
C56687 | Imaging magnetoencephalography direct current offset apply other text | ImagMEGDCOffApplyOthrTxt | Text describing another type of direct-current (DC) offset applied to the filter for magnetoencephalography (MEG) | Text describing another type of direct-current (DC) offset applied to the filter for magnetoencephalography (MEG | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 10:49:16.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C56623 | Imaging magnetoencephalography head movement tolerance value | ImagMEGHeadMoveTolVal | The value representing the amount of head movement tolerance during MEG recording | The value representing the amount of head movement tolerance during MEG recordin | Head movement tolerance during MEG recording | 5 mm;10 mm;Other, specify | 5 mm;10 mm;Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-19 14:46:43.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56721 | Imaging magnetoencephalography spectral time frequency component result | ImagMEGSpecTimeFreqCompRes | Results of the spectral time/frequency components measures/comparison of the magnetoencephalography (MEG) study | Results of the spectral time/frequency components measures/comparison of the magnetoencephalography (MEG) stud | Spectral time/frequency components measures/comparison results | Alphanumeric |
No additional instructions |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 15:11:23.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
||||||||||
C56655 | Imaging magnetoencephalography accompany person in magnetic shielded room indicator | ImagMEGAccPersnMagShldRoomInd | The indicator relating to whether there is an accompanying person in the magnetic shielded room | The indicator relating to whether there is an accompanying person in the magnetic shielded roo | Accompany person in the magnetix shielded room | No;Yes | No;Yes | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 10:26:40.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56666 | Imaging magnetoencephalography scanner data format exported type | ImagMEGScanDataFormExpTyp | The type of data format that was exported from magnetoencephalography (MEG) scanners to local workstations/computers | The type of data format that was exported from magnetoencephalography (MEG) scanners to local workstations/computer | The data format exported from the MEG scanner to local workstations/computers | Elekta/Neuromag;CTF/VSM;European Data Format;Others, specify | .fif;.ds;.edf;Others, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 11:02:03.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C15636 | Imaging comparison P-values number | ImgComparPValNum | P-values used for comparisons between cohorts or the group averages | P-values used for comparisons between cohorts or the group averages | Indicate the p-values used for comparisons between cohorts or the group averages | Numeric Values |
No additional instructions |
Adult;Pediatric | Supplemental-Highly Recommended | 3.00 | 2013-07-16 14:01:43.01 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
|||||||||||
C56700 | Imaging magnetoencephalography reconstruction dipole modeling other text | ImagMEGReconDipMedOthrTxt | Text describing another type of dipole modeling used for reconstruction of the magnetoencephalography (MEG) recording | Text describing another type of dipole modeling used for reconstruction of the magnetoencephalography (MEG) recordin | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 11:41:33.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C56634 | Imaging baseline time | ImagBaselineTIme | The amount of time that the pre-trigger (baseline) lasted | The amount of time that the pre-trigger (baseline) laste | Pre-trigger (base-line) time | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 09:26:38.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond | |||||||||||
C56677 | Imaging magnetoencephalography waveform trigger based average value | ImagMEGWaveTrigAvgVal | The waveform average value for trigger based averaging | The waveform average value for trigger based averagin | Trigger based averaging | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 10:35:03.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||||
C56613 | Imaging magnetoencephalography sensor array type | ImagMEGSensArrayTyp | The type of sensor array used for MEG imaging | The type of sensor array used for MEG imagin | MEG Sensor Array(dewar) Type | Whole Cortex/Head;Partial Coverage;Other, specify | Whole Cortex/Head;Partial Coverage;Other, specify | Alphanumeric |
Choose one |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-19 14:24:31.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
|||||||||
C56711 | Imaging magnetoencephalography topographic distribution other text | ImagMEGTopoDistOthrTxt | Text describing another form of topographic distribution used for analysis of the magnetoencephalography (MEG) data | Text describing another form of topographic distribution used for analysis of the magnetoencephalography (MEG) dat | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 14:10:23.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C56645 | Imaging online filter type | ImagOnLineFiltTyp | The type of on-line filter used for imaging | The type of on-line filter used for imagin | On-line filter | High pass-filter;Low pass-filter;Power-line (60/50) filter | High pass-filter;Low pass-filter;Power-line (60/50) filter | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 09:55:51.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||||
C56656 | Imaging magnetoencephalography magnetic shielded room person count | ImagMEgMagShldRoomPrsnCt | The number of persons accompanying the examiner in the magnetic shielding room, if applicable | The number of persons accompanying the examiner in the magnetic shielding room, if applicabl | If Yes, number of persons | Numeric Values | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-20 10:27:58.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||||
C56688 | Imaging magnetoencephalography evoked elicited neuromagnetic repsonse type | ImagMEGEvoEliNeurRspnsTyp | The type of evoked/elicited neuromagnetic response(s) seen during magnetoencephalography (MEG) processing and analysis | The type of evoked/elicited neuromagnetic response(s) seen during magnetoencephalography (MEG) processing and analysi | Evoked/elicited neuromagnetic responses | Amplitude of response;Number of responses (deflection);Latency of response;Habituation;Other, specify | Amplitude of response;Number of responses (deflection);Latency of response;Habituation;Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 10:51:50.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||||
C56624 | Imaging magnetoencephalography head movement tolerance other text | ImagMEGHeadMoveTolOthrTxt | Text describing another head movement tolerance value used during MEG recording | Text describing another head movement tolerance value used during MEG recordin | Other, specify | Alphanumeric | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-19 14:48:46.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
|||||||||||
C56722 | Imaging magnetoencephalography source location result | ImagMEGSrcLocRes | Results of the source location measures/comparison of the magnetoencephalography (MEG) study | Results of the source location measures/comparison of the magnetoencephalography (MEG) stud | Source location measures/comparison results | Alphanumeric |
No additional instructions |
Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-06-26 15:13:46.0 | Magnetoencephalography (MEG) | Imaging Diagnostics | Assessments and Examinations | 255 |
Free-Form Entry |
- « first
- ‹ previous
- 1
- 2
- 3