CDE Detailed Report
Disease: system
Subdomain Name: Biomechanical Devices
CRF: system
Displaying 101 - 105 of 105
Subdomain Name: Biomechanical Devices
CRF: system
Displaying 101 - 105 of 105
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C56930 | Brain injury peak principal strain value | BrainInjPeakPrincipalStrainVal | The value as related to peak principal strain in analysis of brain injury | The value as related to peak principal strain in analysis of brain injur | Peak Principal strain: | Numeric Values |
recommend 95th percentile peak maximum principal strain value among all elements in the brain mesh. If possible, also recommend reporting where this peak value occurred in the brain. |
Adult;Pediatric | Exploratory | 1.00 | 2017-08-04 08:27:04.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
|||||||||||
C00008 | Age value | AgeVal | Value for participant's age, calculated as elapsed time since the birth of the participant | Value for participant's age, calculated as elapsed time since the birth of the participant | Subject age: | Numeric Values | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:28.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
0 | 1800 | month | ||||||||
C22780 | Date time clock type | DateTimeClockTyp | Type of clock used to record date and time | Type of clock used to record date and tim | am;PM;24-hour clock | am;PM;24-hour clock | Alphanumeric | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659–2668 | Adult;Pediatric | Supplemental | 1.00 | 2016-10-27 12:24:17.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Single Pre-Defined Value Selected |
||||||||||
C56908 | Head impact peak linear acceleration x value | HeadImpPeakLinearAccelerXVal | The value of peak linear acceleration in the x direction in head impact assessment | The value of peak linear acceleration in the x direction in head impact assessmen | Peak linear acceleration x: | Numeric Values | Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-08-03 15:45:50.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
|||||||||||
C57004 | Total record length impact duration | TtlRcLngImpDur | Duration of total record length impact (in ms) | Duration of total record length impact (in ms) | Total record length: | Numeric Values |
Exposure duration / sampling window - Length of time data is collected for a given exposure. Record time in milliseconds, both pretrigger, posttrigger, or pre and post trigger total (milliseconds) |
Cortes N, Lincoln AE, Myer GD, Hepburn L, Higgins M, Putukian M. & Caswell SV. Video Analysis Verification of Head Impact Events Measured by Wearable Sensors. The American Journal of Sports Medicine. 2017;45(10):2379-2387<br />Wu LC, Zarnescu L, Nangia V, Cam B, & Camarillo, DB. A Head Impact Detection System Using SVM Classification and Proximity Sensing in an Instrumented Mouthguard. IEEE Transactions on Bio-Medical Engineering.2014;61(11):2659-2668 | Adult;Pediatric | Supplemental-Highly Recommended | 1.00 | 2017-12-06 12:02:05.0 | Head Kinematics Estimates Form | Biomechanical Devices | Disease%2FInjury Related Events |
Free-Form Entry |
Millisecond |
- « first
- ‹ previous
- 1
- 2
- 3