CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C17941 Spectroscopy geometry voxel slice size inferior superior value SpectroGeomSizeInfSupVal Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported Value, in mm, of voxel or slice inferior-superior size for the spectroscopy scan being reported Spectroscopy c Geometry ii. Voxel or slice size: inferior superior Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C10952 Spectroscopy water suppression type SpectroWaterSupressMethodTyp Indicator of water suppression method used, if any, for the spectroscopy scan being reported Indicator of water suppression method used, if any, for the spectroscopy scan being reported Spectroscopy d Water suppression If yes CHESS;Other, specify CHESS;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C17953 Imaging other nuclei text ImgOthNucleiTxt Text identification of unlisted nuclei in the image being reported Text identification of unlisted nuclei in the image being reported Nuclei Other Alphanumeric No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C12508 Imaging radio frequency coil function type ImgRFCoilFunctTyp The function of the radio frequency (RF) coil used The function of the RF coil used RF Coils Transmit Tx and or Receive Rx Tx;Rx;Tx/Rx Transmit;Receive;Transmit/Receive Alphanumeric

Answer for each RF coil named

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Anatomical Reference Image FOV Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm?).

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17942 Spectroscopy sequence parameter PRESS asymmetry TE1 value SpectroSeqParamPRESSAsymTE1Val Value, in ms, of echo time (TE) 1 for an asymmetric PRESS sequence if used in the scan being reported Value, in ms, of echo time (TE) 1 for an asymmetric PRESS sequence if used in the scan being reported Spectroscopy b Spectroscopy sequence parameters For PRESS is it symmetric or asymmetric? Asymmetric TE1 Numeric Values No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Magnetic Resonance Spectroscopy (MRS) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millisecond