CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C15572 | Imaging diffusion direction count | ImgDiffusionDirCt | Count of diffusion directions in the associated diffusion imaging study | Count of diffusion directions in the associated diffusion imaging study | DTI sequence parameters, Number of diffusion-weighting gradient directions | Numeric Values |
Record the number of diffusion-weighting gradient directions |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-16 14:01:43.01 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name of the scanner software | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C18657 | Imaging diffusion sixth b value | ImgDiffusionSixthBVal | Value, in square millimeters per second, of the sixth b-value used in diffusion acquisition | Value, in square millimeters per second, of the sixth b-value used in diffusion acquisitio | Numeric Values | Adult;Pediatric | Supplemental | 1.00 | 2014-01-08 00:00:00.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | ||||||||||||
C10577 | Imaging signal averages number | ImgSignalAvgNum | Number of signal acquisitions averaged in imaging acquisition | Number of signal acquisitions averaged in imaging acquisition | DTI sequence parameters, Number of signal averages | Numeric Values |
Record the number of signal averages |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
||||||||||
C10594 | Imaging parallel acquisition used indicator | ImgParallelAcquistionUsedInd | Indicator of whether a parallel acquisition method is used in imaging acquisition | Indicator of whether a parallel acquisition method is used in imaging acquisition | Parallel acquisition used | Yes;No | Yes;No | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C17793 | Imaging diffusion fourth b value | ImgDiffusionFourthBVal | Value, in square millimeters per second, of the fourth b-value used in diffusion acquisition | Value, in square millimeters per second, of the fourth b-value used in diffusion acquisitio | DTI sequence parameters, fourth b-value | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C08238 | Imaging repetition gap duration | ImgRepetitionGapDur | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | Duration between successive pulse sequences, in milliseconds, applied to the same slice during imaging acquisition | DTI sequence parameters, Repetition time | Numeric Values |
TR |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:45.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millisecond |