CDE Detailed Report
Disease: system
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 57 of 57
Subdomain Name: Imaging Diagnostics
CRF: files
Displaying 51 - 57 of 57
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C18690 | Imaging analysis software other text | ImgAnlysisSftwrOTH | The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging study | The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging stud | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10682 | Imaging anatomic site | ImgAnatSite | Anatomic site of body part or anatomy scanned in the imaging study | Anatomic site of body part or anatomy scanned in the imaging study | Body part scanned | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify | Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 4.00 | 2024-02-29 15:53:09.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Multiple Pre-Defined Values Selected |
||||||||
C08241 | Imaging field of view axis 1 measurement | ImgFieldViewAxis1Measr | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters | DTI sequence parameters, Field of view | Numeric Values |
Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2) |
No references available | Adult;Pediatric | Supplemental | 3.10 | 2024-02-29 15:47:41.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
millimeter | |||||||||
C17795 | Imaging diffusion third b value | ImgDiffusionThirdBVal | Value, in square millimeters per second, of the third b-value used in diffusion acquisition | Value, in square millimeters per second, of the third b-value used in diffusion acquisitio | DTI sequence parameters, third b-value | Numeric Values |
DTI sequence parameters |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-22 16:57:17.79 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
square millimeter per second | |||||||||
C10586 | Imaging bandwidth value | ImgBandwidthVal | Value, in Hertz per pixel, of bandwidth used in imaging acquisition | Value, in Hertz per pixel, of bandwidth used in imaging acquisitio | DTI sequence parameters, Band width | Numeric Values |
Answer should be recorded in Hx/Pixel |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-25 08:54:08.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Free-Form Entry |
Hertz per pixel | |||||||||
C18703 | Imaging parallel acquisition used other text | ImgParallelAcquistionMethodOTH | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio | Other, specify | Alphanumeric |
No instructions available |
No references available | Adult;Pediatric | Supplemental | 1.00 | 2014-05-27 13:34:46.0 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10683 | Imaging T2 weighted spin-echo acquired indicator | ImgT2WSpinEchoAcquireInd | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction | Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correctio | T2-weighted spin-echo acquired | Yes;No | Yes;No | Alphanumeric |
For B0-susceptibility distortion correction. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Diffusion Tensor Imaging (DTI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |