CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C18690 Imaging analysis software other text ImgAnlysisSftwrOTH The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging study The free-text field related to 'Imaging analysis software name' specifying other text. Name of the software used for data processing or analysis of the imaging stud Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10682 Imaging anatomic site ImgAnatSite Anatomic site of body part or anatomy scanned in the imaging study Anatomic site of body part or anatomy scanned in the imaging study Body part scanned Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Brain;Cervical spine;Thoracic spine;Lumbar spine;Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 4.00 2024-02-29 15:53:09.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C08241 Imaging field of view axis 1 measurement ImgFieldViewAxis1Measr Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters Measurement of axis 1 of the image that is visible through the camera at a particular position in orientation and space in millimeters DTI sequence parameters, Field of view Numeric Values

Answer should be recorded as a dimension (AAxAA) and in millimeters squared (mm2)

No references available Adult;Pediatric Supplemental 3.10 2024-02-29 15:47:41.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

millimeter
C17795 Imaging diffusion third b value ImgDiffusionThirdBVal Value, in square millimeters per second, of the third b-value used in diffusion acquisition Value, in square millimeters per second, of the third b-value used in diffusion acquisitio DTI sequence parameters, third b-value Numeric Values

DTI sequence parameters

No references available Adult;Pediatric Supplemental 3.00 2013-07-22 16:57:17.79 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

square millimeter per second
C10586 Imaging bandwidth value ImgBandwidthVal Value, in Hertz per pixel, of bandwidth used in imaging acquisition Value, in Hertz per pixel, of bandwidth used in imaging acquisitio DTI sequence parameters, Band width Numeric Values

Answer should be recorded in Hx/Pixel

No references available Adult;Pediatric Supplemental 3.00 2013-07-25 08:54:08.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz per pixel
C18703 Imaging parallel acquisition used other text ImgParallelAcquistionMethodOTH The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio Other, specify Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 1.00 2014-05-27 13:34:46.0 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C10683 Imaging T2 weighted spin-echo acquired indicator ImgT2WSpinEchoAcquireInd Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correction Indicator as to whether or not T2-weighted spin-echo data acquired for spatially registering DWI data and performing spatial distortion (B0) correctio T2-weighted spin-echo acquired Yes;No Yes;No Alphanumeric

For B0-susceptibility distortion correction.

No references available Adult;Pediatric Supplemental 3.00 2013-07-24 11:38:01.2 Diffusion Tensor Imaging (DTI) Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

CSV