CDE Detailed Report
Subdomain Name: Imaging Diagnostics
CRF: welcome
Displaying 51 - 56 of 56
CDE ID | CDE Name | Variable Name | Definition | Short Description | Question Text | Permissible Values | Description | Data Type | Disease Specific Instructions | Disease Specific Reference | Population | Classification (e.g., Core) | Version Number | Version Date | CRF Name (CRF Module / Guidance) | Subdomain Name | Domain Name | Size | Input Restrictions | Min Value | Max Value | Measurement Type | External Id Loinc | External Id Snomed | External Id caDSR | External Id CDISC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
C18703 | Imaging parallel acquisition used other text | ImgParallelAcquistionMethodOTH | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisition | The free-text field related to 'Imaging parallel acquisition used type' specifying other text. Type of the parallel acquisition method used in imaging acquisitio | Other, specify | Alphanumeric |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters. |
No references available | Adult;Pediatric | Exploratory | 1.00 | 2014-05-27 13:34:46.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10592 | Imaging flow compensation indicator | ImgFlowCompnsatnInd | Indicator of whether flow compensation was used in imaging acquisition | Indicator of whether flow compensation was used in imaging acquisition | Flow compensation used | Yes;No | Yes;No | Alphanumeric |
If the sequences are different for T1 and T2 sequence parameters, record the T2 parameters as indicated. If they are the same, leave the T2 parameters section blank. If the sequences are different for T1 and FLAIR sequence parameters, record the FLAIR parameters as indicated. If they are the same, leave the FLAIR parameters section blank. DTI sequence parameters |
No references available | Adult;Pediatric | Exploratory | 3.00 | 2013-07-25 08:54:08.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C10931 | Imaging quality technically satisfactory status | ImgQualTechnSatisStat | Status related to whether the quality of the images was technically satisfactory | Status related to whether the quality of the images was technically satisfactory | Quality of images technically satisfactory? | Yes;No | Yes;No | Alphanumeric |
Choose one |
No references available | Adult;Pediatric | Exploratory | 4.00 | 2024-02-29 15:47:51.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C08236 | Imaging scanner software name | ImgScannerSftwrName | Name of the scanner software that runs the imaging camera | Name of the scanner software that runs the imaging camera | Name | Alphanumeric |
Record the scanner software name |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |
|||||||||
C10568 | Imaging radio frequency coil channel count | ImgRFCoilChannelCt | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | Number of the coil channels in the radio frequency (RF) coil used for the imaging scan | RF reciver coil(s) and number of channels | 1;8;12 channels;16;24;32 channels;Other, specify | Single coil;8 channels;12 channels;16 channels;24 channels;32 channels;Other, specify | Alphanumeric |
Record the number of coils for the applicable receiver coils. |
No references available | Adult;Pediatric | Supplemental | 3.00 | 2013-07-24 11:38:01.2 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations |
Single Pre-Defined Value Selected |
||||||||
C18708 | Imaging pulse sequence type other text | ImgPulseSeqTypOTH | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | The free-text field related to 'Imaging pulse sequence type', specifying other text. Type of imaging pulse sequence used | Other, specify | Alphanumeric |
Choose all that apply |
No references available | Adult;Pediatric | Supplemental | 2.00 | 2022-07-01 14:55:04.0 | Magnetic Resonance Imaging (MRI) | Imaging Diagnostics | Assessments and Examinations | 4000 |
Free-Form Entry |