CDE Detailed Report

Disease: Stroke
Subdomain Name: Imaging Diagnostics
CRF: Vessel Imaging Transcranial

Displaying 1 - 50 of 74
CDE ID CDE Name Variable Name Definition Short Description Question Text Permissible Values Description Data Type Disease Specific Instructions Disease Specific Reference Population Classification (e.g., Core) Version Number Version Date CRF Name (CRF Module / Guidance) Subdomain Name Domain Name Size Input Restrictions Min Value Max Value Measurement Type External Id Loinc External Id Snomed External Id caDSR External Id CDISC
C13942 Imaging vessel category ImgVesselCat Indicates vessel category Indicates vessel category Vessels M1;Insular M2;A1;ICA;P1;P2;EC ICA;Vertebral;Basilar M1;Insular M2;A1;Internal Carotid Artery (ICA);P1;P2;EC Internal Carotid Artery (ICA);Vertebral;Basilar Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14015 High intensity transient signal hits count HighIntensTransSignalHitsCt Numeric value counting the number of high intensity transient signals hits Numeric value counting the number of high intensity transient signals hits Number Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999
C13953 Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up indicator COGIFFollowupInd Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up Indicates the consensus on grading intracranial flow obstruction (COGIF) follow-up COGIF Follow-up Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14033 Vasospasm vessel anatomic site VasospasmVesselAntmicSite Indicates vasospasm vessel(s) Indicates vasospasm vessel(s) Vessel(s) ICA;Basilar;MCA;VA Internal carotid artery;Basilar;Middle cerebral artery;Vertebral artery Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14005 Imaging brain death diagnosis result ImgBrainDeathDiagReslt Indicates brain death diagnosis result Indicates brain death diagnosis result Brain Death Reversed Diastolic Flow;Systolic spike;No signals Reversed Diastolic Flow;Systolic spike;No signals Alphanumeric

Select all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C18901 Sickle cell disease vessel anatomic other text SickleCellDisVesselAntmicOTH The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel The free-text field related to 'Sickle cell disease vessel anatomic site' specifying other text. Indicates sickle cell vessel Other, specify Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C13750 Imaging study ID number ImgStudyIDNum Unique identification number assigned to the study or assessment session Unique identification number assigned to the study or assessment sessio Study ID number Alphanumeric

No instructions available

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C13943 Imaging B-mode result ImgBModReslt Indicates B mode Indicates B mode B mode Normal;Occlusion;Stenosis Normal;Occlusion;Stenosis Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14016 High intensity transient signal hits start time HighIntensTransSigHitStartTime Indicates high intensity transient signal hits start time Indicates high intensity transient signal hits start time Start Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13954 Consensus on Grading Intracranial Flow Obstruction (COGIF) - follow-up date and time COGIFFollowupDateTime The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-up The date and time for consensus on grading intracranial flow obstruction (COGIF) follow-u Date, Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C14034 Vasomotor response (VMR) vessel anatomic site VMRVesselAntmicSite Indicates vasomotor response (VMR) vessel type Indicates vasomotor response (VMR) vessel type Vessel MCA;Other, specify Middle cerebral artery;Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14006 Imaging stenosis percentage value ImgStenosisPercentageVal Indicates stenosis percentage value Indicates stenosis percentage value Percent Stenosis Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 99 percent
C18903 Vasomotor response (VMR) vessel anatomic other text VMRVesselAntmicOTH The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type The free-text field related to 'Vasomotor response (VMR) vessel anatomic site' specifying other text. Indicates vasomotor response (VMR) vessel type Other, specify Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 4000

Free-Form Entry

C13751 Imaging acquisition reason ImgAcquisitionRsn Describes why the imaging study was performed Describes why the imaging study was performed Scan purpose Initial;Monitoring Initial;Monitoring Alphanumeric

Select all that apply

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C13944 Imaging color flow indicator ImgColorFlowInd Indicates color flow Indicates color flow Color flow Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14020 Sickle cell disease vessel anatomic site SickleCellDisVesselAntmicSite Indicates sickle cell vessel Indicates sickle cell vessel Vessel(s) MCA;Other, specify Middle cerebral artery;Other, specify Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C13955 Imaging transcranial color-coded sonography symptomatic indicator ImgTCCSSymptomaticInd Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) Indicates symptomatic presentation by Transcranial Color-Coded Sonography (TCCS) Symptomatic Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14035 VMR response result VMRResponseReslt Indicates vasomotor response (VMR) response result Indicates vasomotor response (VMR) response result VMR Abnormal;Normal Abnormal;Normal Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14007 Imaging Transcranial Doppler (TCD) findings result type ImgTCDFindResltTyp Indicates Transcranial Doppler (TCD) findings Indicates Transcranial Doppler (TCD) findings Findings Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) Reversed Diastolic Flow;Systolic spike;No signals;Reduced upstroke/Pulsatility Index (PI) Alphanumeric

Select all that apply. Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58867 Imaging chronic stroke type ImgChronStrkStudTyp Indicates chronic stroke type Indicates chronic stroke type Chronic Stroke Hemisphere;Eye;Vetebrobasilar Hemisphere;Eye;Vetebrobasilar Alphanumeric

Indicate the type of chronic stroke

No references available Adult;Pediatric Supplemental 1.00 2020-05-18 11:12:20.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13899 Imaging probe type text ImgProbeTypTxt The text describing the type of imaging probe Describes imaging probe type Type Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C13945 Imaging spectrum depth measurement ImgSpectrumDepthMeasr Indicates spectrum depth measurement (mm) Indicates spectrum depth measurement (mm) Depth Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 millimeter
C14021 Sickle cell disease blood flow velocity measurement SickleCellVelBldFlowMeasr The velocity measurement blood flow relative to sickle cell disease The velocity measurement blood flow relative to sickle cell diseas Velocity Numeric Values

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 centimeter per second
C13956 High intensity transient signal hits duration HighIntensTransSignalHitsDur Indicates high intensity transient signal hits duration time (msec) Indicates high intensity transient signal hits duration time (msec) Duration time Numeric Values

Indicate duration time in units of msec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 millisecond
C14036 Breath-holding index result BreathHoldingIndexReslt Indicates Breath-holding index (BHI) result Indicates breath-holding index (BHI) result Breath-holding index (BHI) Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations 255

Free-Form Entry

C14008 Imaging window quality category ImgWindowQualityCat Indicates window quality category Indicates window quality category Insonation window Temporal;Posterior;Orbital Temporal;Posterior;Orbital Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58868 Imaging transient ischemic attack type ImgTIATyp Indicates type of transient ischemic attack Indicates type of transient ischemic attack TIA Hemisphere;Eye;Vetebrobasilar Hemisphere;Eye;Vetebrobasilar Alphanumeric

Indicate the type of TIA

No references available Adult;Pediatric Supplemental 1.00 2020-05-18 11:20:04.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13900 Imaging probe frequency ImgProbeFreq Indicates imaging probe frequency (Hz) Indicates imaging probe frequency (Hz) Frequency Numeric Values

Indicate frequency in units of Hz

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

Hertz
C13946 Imaging spectrum angle correction indicator ImgSpectrumAngleCorrectionInd Indicates spectrum angle correction Indicates spectrum angle correction Angle correction Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14023 Sickle cell disease diagnosis result SickleCellDiagnosReslt Indicates sickle cell diagnosis result Indicates sickle cell diagnosis result Sickle Cell (indication for study) Abnormal;Normal;Conditional Abnormal;Normal;Conditional Alphanumeric

Associated form contains data elements collected when an imaging study is performed using TCCS to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of microembolic signals; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13957 High intensity transient signal hits intensity value HighIntensTransSignalHitsVal Indicates high intensity transient signal hits intensity value (dB) Indicates high intensity transient signal hits intensity value (dB) Intensity Numeric Values

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

decibel
C14037 Imaging power M mode left middle cerebral artery result type ImgPowerMModeLeftMCAResTyp Indicates power M mode for left middle cerebral artery (MCA) result Indicates power M mode for left middle cerebral artery (MCA) result Left MCA Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Supplemental 4.00 2021-11-19 15:28:20.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14009 Imaging window quality result ImgWindowQualityReslt Indicates window quality result for all categories Indicates window quality result for all categories Window quality Fair;Excellent;Poor Fair;Excellent;Poor Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; and Flow direction)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C58905 Imaging transcranial ultrasound performed type ImgTranscrnUltrsndPerfmdTyp Indicates the ultrasound type Indicates the ultrasound type Ultrasound Type Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) Transcranial Color-coded Real-time Sonography (TCCS);Transcranial Doppler (TCD) Alphanumeric

Indicate ultrasound type

No references available Adult;Pediatric Supplemental 1.00 2020-05-19 14:23:40.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13901 Imaging patient type ImgPatientTyp Indicates imaging patient type Indicates imaging patient type Patient type Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt Asymptomatic;Acute Stroke;Chronic Stroke;Brain Edema;Vasopasm;Chronic TIA;Brain Death;Sickle Cell;Arteriovenous malformation;Monitoring;Right Shunt;Left Shunt Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13947 Imaging peak velocity measurement ImgPeakVelocityMeasr Indicates peak velocity measurement (cm/sec) Indicates peak velocity measurement (cm/sec) Peak velocity Numeric Values

Indicate peak velocity in units of cm/sec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 centimeter per second
C14024 Vasospasm criterion value VasoCriterionVal Indicates vasospasm criterion value Indicates vasospasm criterion value Criterion Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13960 High intensity transient signal hits vessel anatomic site HighIntensTransSigHitAnatSite Indicates high intensity transient signal hits vessel category Indicates high intensity transient signal hits vessel category High intensity transient signal hits M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar M1;A1;P1;Siphon;Ophthalmic;Vert;Basilar Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C14038 Imaging power M mode right middle cerebral artery result type ImgPowerMModeRightMCAResTyp Indicates power M mode for right middle cerebral artery (MCA) result Indicates power M mode for right middle cerebral artery (MCA) result Right MCA Absent;High Resistance;Low Resistance Absent;High Resistance;Low Resistance Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits) Highly recommended for Stroke imaging studies

No references available Adult;Pediatric Supplemental 4.00 2021-11-19 15:52:18.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14010 Intracranial stenosis collateral vessel anatomic site IntracrnStnoColltVsslAntmicSit Indicates intracranial stenosis collateral vessel(s) Indicates intracranial stenosis collateral vessel(s) Vessel(s) ICA;Basilar;MCA;Other, specify;VA Internal carotid artery;Basilar;Middle cerebral artery;Other, specify;Vertebral artery Alphanumeric

Use the specific codelist that corresponds to the type of imaging done

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Multiple Pre-Defined Values Selected

C58906 Vasospasm resistive index value VasospasmRestistIndexVal Indicates vasospasm resistive Index (RI) Indicates vasospasm resistive Index (RI) Resistive index Numeric Values

(RI) These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 1.00 2020-05-19 17:46:31.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13902 Imaging acute stroke study type ImgAcutStokStudTyp Indicates imaging acute stroke study type Indicates imaging acute stroke study type Indicate study type Initial;Follow-up 1;Follow-up 2 Initial;Follow-up 1;Follow-up 2 Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13948 Imaging mean blood velocity measurement ImgMeanBloodVelocityMeasr Indicates mean velocity measurement (cm/sec) of blood Indicates mean velocity measurement (cm/sec) of blood Mean velocity Numeric Values

Indicate mean velocity in units of cm/sec

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 centimeter per second
C14025 Vasospasm Lindegaard ratio value VasoLinegaardRatioVal Indicates vasospasm lindegaard ratio result Indicates vasospasm Lindegaard ratio result Lindegaard ratio Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C13961 High intensity transient signal hits present indicator HighIntensTransSigHitPresInd Indicates presence of high intensity transient signals hits Indicates presence of high intensity transient signals hits High intensity transient signal hits Yes;No Yes;No Alphanumeric

These CDEs are collected when an imaging study is performed using Transcranial Imaging to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and High intensity transient signal hits)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14051 High intensity transient signal hits end time HighIntensTransSigHitEndTime Indicates high intensity transient signal hits end time Indicates high intensity transient signal hits end time End Time Date or Date & Time

Record the date/time according to the ISO 8601, the International Standard for the representation of dates and times (http://www.iso.org/iso/home.html). The date/time should be recorded to the level of granularity known (e.g., year, year and month, complete date plus hours and minutes, etc.).

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

C14011 Intracranial stenosis present indicator IntracranStenosisPresentInd Indicates presence of intracranial stenosis Indicates presence of intracranial stenosis Intracranial stenosis Yes;No Yes;No Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13903 Imaging interpretation site location ImgInterpretSiteLoc Indicates imaging interpretation site Indicates imaging interpretation site Interpretation site Onsite;Offsite Onsite;Offsite Alphanumeric

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C13949 Imaging flow/probe direction type ImgFlowProbDireTyp Indicates flow/probe direction Indicates flow/probe direction Direction of Probe Towards;Away from Towards;Away from Alphanumeric

Associated form contains data elements collected when an imaging study is performed using Transcranial Imaging to examine the brain vessels and evaluate cerebral hemodynamics. (Examples of CDEs included: COGIF score; Number of high intensity transient signal hits; and Vasomotor response)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Single Pre-Defined Value Selected

C14026 Intracranial pressure imaging result ICPReslt Indicates intracranial pressure (ICP) imaging result Indicates vasospasm intracranial pressure (ICP) imaging result Intracranial pressure Numeric Values

These CDEs are collected when an imaging study is performed using TCD to assess the intra cranial cerebral (brain) circulation; the velocity of blood flow through the brain's blood vessels is captured along with other findings. (Examples of CDEs included: Peak velocity; Flow direction; and Microembolic signal intensity)

No references available Adult;Pediatric Supplemental 3.00 2013-06-21 00:00:00.0 Vessel Imaging Transcranial Imaging Diagnostics Assessments and Examinations

Free-Form Entry

0 999 millimeter of mercury
CSV